Chimney Draught Calculator: Will Your Flue Pull Enough?
A chimney pulls because the hot gas inside it is lighter than the cold air outside. This calculator works out that pull, the draught, in pascals from your flue height and the two temperatures, then checks it against the figure your stove asks for. The point most people miss: draught depends on the temperature difference, not the heat alone. The same 6m flue that pulls hard on a cold night can pull less than a third as well when the flue is cool and it is mild outside, which is why fires smoke when first lit and on warm days.
Work out your chimney draught
The figure is the theoretical draught: the pull a perfectly smooth, airtight flue would make with no wind. A real flue loses some of it to friction, bends, the cowl and the gas cooling on the way up, so the draught measured at the stove is always lower. That is why the calculator wants a comfortable margin over your stove's figure, not just a match.
How the draught maths works
Air gets lighter as it warms. At sea level a cubic metre of air weighs about 1.27kg at 5°C but only about 0.75kg at 200°C. A column of hot gas in the flue therefore weighs less than a column of outside air of the same height, and the difference in weight per square metre is the pressure that drives air into the stove and smoke up the chimney.
The calculator uses the standard stack effect formula: draught in pascals equals gravity times flue height times the difference between the outside air density and the flue gas density. Each density comes from the gas law, using the air pressure for your altitude and the temperature in kelvin. Flue gas from burning wood is treated as having the same density as air at the same temperature, which is close enough for a household chimney.
Worked through for a 6m flue, 5°C outside and 200°C average in the flue, the result is about 31 Pa. Drop the flue gas to 60°C and raise the outside to 15°C, a cold flue on a mild day, and the same chimney makes under 10 Pa, less than a third as much.
Why a fire smokes when first lit
When the stove is cold, the flue is full of air at roughly room or outside temperature, so there is almost no difference in weight and almost no draught. Smoke from a newly lit fire has nowhere to go but the room. Warming the flue quickly fixes it: top-down lighting, plenty of kindling, the air controls fully open, and the door left ajar for the first few minutes on stoves that allow it. Once the flue is hot, the draught builds and the stove settles.
The same physics explains smoky fires in spring and autumn. The outside air is warmer, so the gap between the two temperatures is smaller and the chimney pulls less. A lazy, low burn makes it worse because the flue gas is cooler too.
When the draught is too weak
If the calculator shows little or no margin, the usual fixes, in rough order of cost, are: burn drier logs so the fire runs hotter, warm the flue properly at lighting, fit or insulate a liner so the gas stays hot as it rises, and add height to the chimney. A taller flue is the most direct fix because draught rises in step with height. Approved Document J sets a minimum flue height of 4.5m for a stove, measured from the top of the appliance, and the flue has to finish high enough above the roof; our flue height calculator covers the roof rules.
Weak draught is not always the chimney. A room without enough air supply cannot feed the stove however hard the flue pulls, and an extractor fan in the same house can fight the chimney. Check the vent with the air vent calculator and make sure the liner is the right diameter with the flue liner size calculator.
When the draught is too strong
A tall chimney on a cold night can pull far more than the stove was designed for. The fire roars, logs vanish, the air controls stop having much effect and heat goes up the flue instead of into the room. Many stove manuals give a maximum as well as a minimum draught. If you are well above it, an installer can fit a draught stabiliser, a weighted flap that lets room air into the flue to hold the draught steady.
This calculator is a guide to the physics, not a test of your chimney. The only way to know the real draught is to measure it: a HETAS registered installer or chimney sweep can take a reading with a manometer at the flue with the stove running, and a smoke test will show whether the flue is sound.
Want the seasoning calendar and our log-price watch in your inbox?
Join the Kindling List